Manual setting tool for ENSAT® M4 socket
Specifications
Shape | manuel pr douille |
Diameter | N°4 |
Description :
Pull sleeve down. Loosen the 2 locking screws. Unscrew or screw on the threaded end. The position of the flat for the 2 locking screws is indicated by a yellow mark. When reassembling, tighten the 2 screws evenly. Fit the ball bearing and reassemble the bushing, which must be locked by the balls. The bushing must turn easily to ensure correct tool operation. If the Ensat is to be countersunk more than 0.2 mm from the surface of the workpiece, the guide ring must be reduced: 0.1 to 0.2 mm smaller than the Ensat receiving hole.